Podpora
Detaily
View of the cable
The Fibertechnic DAC 2J Z-XOTKtcdD cable with Corning SMF-28 Ultra fibers (L79204) is designed for installataion directly in the ground. It has a HDPE sheath with high crush resistance (4000 N), which also makes it resistant to low temperatures. It can be used on the last mile of a FTTH system, as well as in any installation that requires terrestrial cables, where casing pipes cannot be used.
The cable can also be installed in existing telecommunication ducts: the maximum pulling force during installation equals 1200 N.
The central tube contains two G.652D fibers.
The central tube is filled with gel to protect fibers against humidity and vibrationa, while the cable as such has a waterblock design. It is additionally reinforced with 2 FRP rods with a diameter of 0.9 mm.
Despite its high mechanical resistance, the cable is very easy to process. No dedicated tools are required to remove the outer sheath: a simple cleaver (to perform a cut of several centimeters along the central tube) and a pair of pliers (to tear up the outer sheath with FRP rods) are all you need. To cut the tube, use the Ideal L5922 stripper.
Key features
- HDPE sheath and structure allowing to deploy the cable directly in the ground
- Crush resistance: 4000 N
- Max. pulling force: 1200 N
- 2 x FRP rods (0.9 mm)
- Central tube filled with hydrophobic gel
Specifications
Name | Fibertechnic DAC Z-XOTKtcdD |
Code | L79202 |
Number of fibers | 2 |
Fiber type | G.652D Corning |
Number of tubes | 1 |
Tube diameter | 2 mm |
Cable diameter | 6 mm |
Sheath (jacket) | HDPE |
Reinforcement | 2x FRP rods (0.9 mm) |
Max. pulling force (during installation) | 1200 N |
Max. pulling force (during operation) | 800 N |
Crush resistance | 4000 N |
Operating temperature | -20...+70°C |
Min. bending radius | 120 mm |
Weight | 48 kg/km |
Technické dáta
Product type | Fiber optic cable | ||
Brand | FIBERTECHNIC | ||
Name | Z-XOTKTCDD | ||
Cable type | |||
Number of fibers | 2 | ||
Fibers | type | ||
Fibers | standard | G.657A1 | |
buffer | 250 μm | ||
CPR class | |||
Outer sheath material | HDPE | ||
Hydrophobic gel | No | ||
Gain | |||
Central tube | Yes | ||
Outer diameter | mm | 6 | |
Central tube diameter | mm | 2 | |
Crush strength | N | 4000 | |
Maximum pulling force | dynamic | N | 1200 |
Maximum pulling force | static | N | 800 |
Min. bending radius | static | mm | no data |
Min. bending radius | installation | mm | 120 |
Temperature range | operation | °C | -20...70 |
Temperature range | installation | °C | no data |
storage | °C | no data | |
Weight | kg/km | 34 | |
Cable length | m |