Tovar bol stiahnutý z ponuky
Podpora
Detaily
View of the cable
The Fibertechnic DAC 24J Z-XOTKtcdD cable with Corning SMF-28 Ultra fibers (L79224) is designed for installataion directly in the ground. It has a HDPE sheath with high crush resistance (4000 N). The cable is also resistant to low temperatures. It can be used on the last mile of a FTTH system, as well as in any installation that requires terrestrial cables, where casing pipes cannot be used.
The cable can also be installed in existing telecommunication ducts: the maximum pulling force during installation equals 1200 N.
The central tube contains 24 single-mode G.652D fibers.
The central tube is filled with gel to protect fibers against humidity and vibrationa, while the cable as such has a waterblock design. It is additionally reinforced with 2 FRP rods with a diameter of 0.9 mm.
Despite its high mechanical resistance, the cable is very easy to process. No dedicated tools are required to remove the outer sheath: a simple cleaver (to perform a cut of several centimeters along the central tube) and a pair of pliers (to tear up the outer sheath with FRP rods) are all you need. To cut the tube, use the Ideal L5922 stripper.
Key features
- HDPE sheath and structure allowing to deploy the cable directly in the ground
- Crush resistance: 4000 N
- Max. pulling force: 1200 N
- 2 x FRP rods (0.9 mm)
- Central tube filled with hydrophobic gel
Specifications
Name | Fibertechnic DAC Z-XOTKtcdD |
Code | L79224 |
Number of fibers | 24 |
Fiber type | G.652D Corning |
Number of tubes | 1 |
Tube diameter | 2 mm |
Cable diameter | 6 mm |
Sheath (jacket) | HDPE |
Reinforcement | 2x FRP rods (0.9 mm) |
Max. pulling force (during installation) | 1200 N |
Max. pulling force (during operation) | 800 N |
Crush resistance | 4000 N |
Operating temperature | -20...+70°C |
Min. bending radius | 120 mm |
Weight | 48 kg/km |
Technické dáta
Product type | Fiber optic cable | ||
Brand | FIBERTECHNIC | ||
Name | Z-XOTKTCDD | ||
Cable type | |||
Number of fibers | 24 | ||
Fibers | type | ||
standard | G.652D | ||
buffer | 250 μm | ||
CPR class | |||
Outer sheath material | HDPE | ||
Hydrophobic gel | No | ||
Gain | |||
Central tube | Yes | ||
Outer diameter | mm | 6 | |
Central tube diameter | mm | 2 | |
Crush strength | N | 4000 | |
Maximum pulling force | dynamic | N | 1200 |
static | N | 800 | |
Min. bending radius | static | mm | no data |
installation | mm | 120 | |
Temperature range | operation | °C | -20...70 |
installation | °C | no data | |
storage | °C | no data | |
Weight | kg/km | 48 | |
Cable length | m |