A short instructional video on crimping RJ-45 connector on a category 6 UTP cable, according to the EIA/EIA 568B standard. The items used: NETSET U/UTP cat. 6 cable, 8-pin RJ-45 modular plug, modular plug boot, HT-210N crimping tool, cable tester NS-468AT.
Cena s DPH | Zľava | Počet | Platnosť |
---|---|---|---|
€485.77 | 0 % | od 1 ks. |
• Kategória 6
• Aplikácia: v interiéri
• Povrch LSZH
• Trieda horľavosti B2ca-s1a-d1-a1
• Priemer vodiča 0,55 mm (24 AWG)
Detaily
- materiály najvyššej kvality, perfektné spracovanie potvrdené 15 ročná záruka,
- trieda horľavosti B2ca-s1a-d1-a1
- predvýrobná kontrola kvality surovín a povýrobná kontrola kvality hotového výrobku,
- značka metra,
- jednožilové medené vodiče s priemerom 0,55 mm,
- izolácia jadra z HDPE, izolačná, farbená v hmote, priemer jadra: Ø 0,98 mm, farby izolácie jadra: bielo-zelená/zelená, bielo-oranžová/oranžová, bielo-hnedá/hnedá, bielo-modrá / modrá,
- plášť kábla vyrobený z materiálu, ktorý vyhovuje LSZH, vonkajší priemer Ø 6,4 mm,
- chyba veľkosti tlače max. 0,5 %
EN50575:2014, EN60332-1-2:2004, EN50399:2011, EN60754-2:2014, EN 13501-6:2014.
- Return Loss (odrazový útlm)
Frekvencia [MHz] | Výsledok (min.) [dB] |
1 | 20,0 |
4 | 23,0 |
8 | 24,5 |
10 | 25,0 |
16 | 25,0 |
20 | 25,0 |
25 | 24,3 |
31,25 | 23,6 |
62,5 | 21,5 |
100 | 20,1 |
200 | 18 |
250 | 17,3 |
- Útlm
Frekvencia [MHz] | Výsledok (min.) [dB] |
1 | 2,03 |
4 | 3,78 |
8 | 5,32 |
10 | 5,95 |
16 | 8,47 |
25 | 9,51 |
31,25 | 10,67 |
62,5 | 15,38 |
100 | 19,8 |
200 | 28,98 |
250 | 32,85 |
- NEXT (presluchy na blízkom konci)
Frequency [MHz] | Result (min.) [dB] |
1 | 74.3 |
4 | 65.3 |
8 | 60.8 |
10 | 59.3 |
16 | 56.2 |
20 | 54.8 |
25 | 53.3 |
31.25 | 51.9 |
62.5 | 47.7 |
100 | 44.3 |
200 | 39.8 |
250 | 38.3 |
- PSNEXT (súčet výkonu na konci presluchu)
Frekvencia [MHz] | Výsledok (min.) [dB] |
1 | 72,3 |
4 | 63,3 |
8 | 58,8 |
10 | 57,3 |
16 | 54,2 |
20 | 51,3 |
31,25 | 49,9 |
62,5 | 45,4 |
100 | 42,3 |
200 | 37,8 |
250 | 36,3 |
- ELFEXT (testovanie straty presluchu na rovnakej úrovni)
Frekvencia [MHz] | Výsledok (min.) [dB] |
1 | 67,8 |
4 | 55,8 |
8 | 49,7 |
10 | 47,8 |
16 | 43,7 |
20 | 41,8 |
25 | 39,8 |
31,25 | 37,9 |
62,5 | 31,9 |
100 | 27,8 |
200 | 21,8 |
250 | 19,8 |
- PSELFEXT (testovanie straty presluchu na vzdialenom konci na rovnakej úrovni)
Frequency [MHz] | Result (min.) [dB] |
1 | 64.8 |
4 | 52.8 |
8 | 46.7 |
10 | 44.8 |
16 | 40.7 |
20 | 38.8 |
25 | 36.8 |
31.25 | 34.9 |
62.5 | 28.9 |
100 | 24.8 |
200 | 18.8 |
250 | 16.8 |
Technické dáta
Name | NETSET U/UTP cat. 6 | ||
Product type | |||
Manufacturer | Dipol | ||
Brand | NETSET | ||
Cable type | U/UTP | ||
Aplikácie | |||
Category | 6 | ||
Cable length | m | 500 | |
CPR class | B2ca s1a,d1,a1 | ||
Fyzikálne vlastnosti | |||
Conductor | Material | Cooper | |
Diameter | mm | 0,55 | |
Conductor insulation | Material | HDPE (polyethylene) | |
Diameter | mm | 0,98 | |
Twisted pairs | colors | white-brown/brown, white-blue/blue, white-orange/orange, white-green/green | |
Twisted pair shield | Material | Al/Mylar | |
sheath | Diameter | mm | 6,4 |
thickness | mm | 0,75 | |
Color | RAL7032 (gray) | ||
Gel filled | No | ||
Carrier cable | No | ||
Rip-cord | Yes | ||
Spline | No | ||
Length marker print error | <0.5 | ||
Elektrické parametre | |||
Impedance | Ohm | 100 | |
Delay skew | ns/100 m | <45 | |
Asymmetry in capacitance of transmission paths to the ground | pF/100 m | 330 | |
DC resistance | Ohm/100 m | 9,38 | |
Resistance asymmetry | <5 | ||
Return Loss | 1 MHz | ≥dB | 20 |
4 MHz | ≥dB | 23 | |
8 MHz | ≥dB | 24,5 | |
10 MHz | ≥dB | 25 | |
16 MHz | ≥dB | 25 | |
20 MHz | ≥dB | 25 | |
25 MHz | ≥dB | 24,3 | |
31.25 MHz | ≥dB | 23,6 | |
62.5 MHz | ≥dB | 21,5 | |
100 MHz | ≥dB | 20,1 | |
200 MHz | ≥dB | 18 | |
250 MHz | ≥dB | 17,3 | |
Loss | 1 MHz | ≤dB | 2 |
4 MHz | ≤dB | 3,78 | |
8 MHz | ≤dB | 5,32 | |
10 MHz | ≤dB | 5,95 | |
16 MHz | ≤dB | 8,47 | |
20 MHz | ≤dB | 9,3 | |
25 MHz | ≤dB | 9,51 | |
31.25 MHz | ≤dB | 10,67 | |
62.5 MHz | ≤dB | 15,38 | |
100 MHz | ≤dB | 19,8 | |
200 MHz | ≤dB | 28,98 | |
250 MHz | ≤dB | 32,85 | |
NEXT (near-end crosstalk) | 1 MHz | ≤dB | 74,3 |
4 MHz | ≤dB | 65,3 | |
8 MHz | ≤dB | 60,8 | |
10 MHz | ≤dB | 59,3 | |
16 MHz | ≤dB | 56,2 | |
20 MHz | ≤dB | 54,8 | |
25 MHz | ≤dB | 53,3 | |
31.25 MHz | ≤dB | 51,9 | |
62.5 MHz | ≤dB | 47,7 | |
100 MHz | ≤dB | 44,3 | |
200 MHz | ≤dB | 39,8 | |
250 MHz | ≤dB | 38,3 | |
PSNEXT (power sum near-end crosstalk) | 1 MHz | ≥dB | 72,3 |
4 MHz | ≥dB | 63,3 | |
8 MHz | ≥dB | 58,8 | |
10 MHz | ≥dB | 57,3 | |
16 MHz | ≥dB | 54,2 | |
20 MHz | ≥dB | 52,8 | |
25 MHz | ≥dB | 51,3 | |
31.25 MHz | ≥dB | 49,9 | |
62.5 MHz | ≥dB | 45,4 | |
100 MHz | ≥dB | 42,3 | |
200 MHz | ≥dB | 37,8 | |
250 MHz | ≥dB | 36,3 | |
ELFEXT | 1 MHz | ≥dB | 67,8 |
4 MHz | ≥dB | 55,8 | |
8 MHz | ≥dB | 49,7 | |
10 MHz | ≥dB | 47,8 | |
16 MHz | ≥dB | 43,7 | |
20 MHz | ≥dB | 41,8 | |
25 MHz | ≥dB | 39,8 | |
31.25 MHz | ≥dB | 37,9 | |
62.5 MHz | ≥dB | 31,9 | |
100 MHz | ≥dB | 27,8 | |
200 MHz | ≥dB | 21,8 | |
250 MHz | ≥dB | 19,8 | |
PSELFEXT (power sum far-end crosstalk) | 1 MHz | ≥dB | 64,8 |
4 MHz | ≥dB | 52,8 | |
8 MHz | ≥dB | 46,7 | |
10 MHz | ≥dB | 44,8 | |
16 MHz | ≥dB | 40,7 | |
20 MHz | ≥dB | 38,8 | |
25 MHz | ≥dB | 36,8 | |
31.25 MHz | ≥dB | 34,9 | |
62.5 MHz | ≥dB | 28,9 | |
100 MHz | ≥dB | 24,8 | |
200 MHz | ≥dB | 18,8 | |
250 MHz | ≥dB | 16,8 | |
Mechanické vlastnosti | |||
Pracovná teplota | °C | -20...+70 | |
Installation temperature | °C | 0...+50 | |
Minimum bending radius for indoor installation | Diameter | >8 | |
Packaging | |||
Spool | Diameter | mm | 380 |
Width | mm | 385 | |
priemer otvoru cievky | mm | 33 |
Filmy
How to attach RJ-45 connector to cat 5 UTP cable. Male RJ-45 connector J2008 (8P8C category 5e for UTP/FTP cables with solid wires) used for computer network cables. NETSET BOX UTP CAT 5e E1408 cable is the highest-quality twisted pair cable designed for professional data transmission systems inside buildings (structural wiring, LANs). Crimping Tool HT-210N J9210 for RJ-45 plugs. Cable Tester (RJ-45, RJ-11) N7055 helps installers to build LAN systems and service existing networks. It tests cable continuity, detects shorts circuits and incorrect connections. The device can be used for UTP/FTP cables terminated with RJ-45 connectors or for telephone cables terminated with RJ-11 phone plugs.